DATE OF SURGERY: 05/23/2026 11:09 PM
PRE-OP DIAGNOSIS: Leiomyoma Uteri
POST-OP DIAGNOSIS: Leiomyoma Uteri
PROCEDURE: daVinci Laparoscopic Total Hysterectomy/BSO
EBL: Minimal
SPECIMENS: Uterus, Fallopian Tubes, and Ovaries
CONDITION: excellent
Description of procedure
The patient was brought to the operating room and general endotracheal was initiated. The patient was then prepped and draped in the usual sterile fashion in the dorsal lithotomy position with Allen stirrups. The time out safety protocol was called out by the surgeon and affirmed by all personnel present. . The surgeon changed gloves and moved to the abdomen. An 8mm umbilical incision was made. . The camera was then introduced, and the pelvis was inspected with the findings as described above. . The patient was placed in trendelenburg. The daVinci patient cart was then docked in the usual manner without difficulty. Bipolar graspers and monopolar endoshears were introduced under direct visualization. The surgeon then moved to the surgeon console. The harmonic scalpel and/or endoscopic shears were used to lyse the adhesions as described in the findings. Good hemostasis was confirmed. The left adnexa was then elevated with an atraumatic grasper. The ureter was visualized transperitoneally and noted to be peristaltic and well away. The bipolar and monopolar cautery with than used in a coordinated fashion to coagulate and cut the infundibulo-pelvic ligament. The round ligament and broad ligament were taken down up to but not through the uterine vessels. The bladder flap was then developed. Good hemostasis was ensured. The same was performed on the opposing side without difficulty. The bladder flap was then competely developed. The uterine vessels were then coagulated and cut. Once the cervical collar was well visualized through the vagina, the vagina was incised and cut circumferentially. The uterus was completely freed, then removed through the cuff but left in the vagina to ensure maintenance of the pneumoperitoneum. The vaginal cuff was then re-approximated using running 2-0 V-lock suture. Again, the ureters were visualized transperitoneally and noted to be peristaltic and well away from the surgical sites. All pedicles were reinspected and noted to be hemostatic under reduced intra abdominal pressure. The patient cart was then undocked from the patient and the ports were removed. The port sites were reclosed using 4-0 Vicryl. Bupivacaine was injected for post op analgesia. Two Alice clamps were used to grasp the anterior vaginal mucosa. Central injection with xylocaine and epinephrine was then performed. Strully scissors were used to create central incision, and dissect the vaginal mucosa away from the underlying tissue. Pratt clamps were used on the vaginal mucosa. The underlying tissue was then imbricated using interrupted 2-0 Vicryl. The excess vaginal mucosa was trimmed and sent to pathology. The mucosa was then reapproximated with a running locking stitch. Two alice clamps were used to grasp the posterior vaginal mucosa on each opposing side. Central injection with xylocaine and epinephrine was then performed. Strully scissors were used to create central incision, and dissect the vaginal mucosa away from the underlying tissue. Pratt clamps were used on the vaginal mucosa. The underlying tissue was then imbricated using interrupted 2-0 Vicryl, including plication of the levators. The excess vaginal mucosa was trimmed and sent to pathology. The mucosa was then reapproximated with a running locking stitch. Normal vaginal caliber and length were confirmed.Two allice clamps were used to grasp the posterior vaginal mucosa on each opposing side. A central injection with xylocaine and epinephrine was then performed. Strully scissors were used to create a central incision, and dissect the vaginal mucosa away from the underlying tissue. Lateral vaginal wall retractors were used to aid in exposing the sacro spinous ligament. The Capio suture passer was then used to place a 0-prolene suture in the ligament. The other end was sutured to the vaginal apex, and the tied down, elevating the vaginal apex. Good hemostasis was confirmed. Any excess vaginal mucosa was trimmed and sent to pathology. The mucosa was then reapproximated with a running locking stitch. Normal vaginal caliber and length were confirmed Two allice clamps were used to grasp the para urethral tissue, and the sub-urethral tissue was incised with a scalpel. The lateral urethral space was the exposed with blunt and sharp dissection. A trans urethral stent was placed in a foley catheter, and placed in the urethra for lateral deflection to reduce the chance of injury during trocar placement. The vaginal tape and trocars where assembled and prepared for placement. The trocar was then placed lateral to the urethra, and a stab incision on the mons pubis allowed passage of the trocar. The same was performed on the other side without difficulty. Cystocopy was then performed to insure the bladder was intact. The trocars was then removed, leaving the tape under the urethra in a tension free position. The positioning was aided using the mayo scissors as a spacer under the urethra. The excess tape was trimmed on the mons. The skin incisions where reapproximated with 4-0 Vicryl and or steri strips. The vaginal mucosa was reapproximated using 2-0 Vicryl, and a foley catheter was anchored. Good urethral support was confirmed. The patient was then brought out of anesthesia and transferred to the recovery room in excellent condition.

Blue link = choose; green = chosen. Click any to change. Copy resolves blue links to their default text.